Search

Appliance Parts & Accys.
  Accessories
  Jenn Air Cartridges

  Replacement Parts
 
Trash Compactor Bags
  Water Filters
  More...

Fire Safety Equipment
  Auxiliary Devices

  Carbon Monoxide Alarms
  Escape Ladders
  Fire Extinguishers

  Smoke Alarms
  More...

Heating Equipment

  Baseboard Heaters

  Ceiling Heaters
  Commercial Heaters
  Fan Forced Heaters

  Furnace Igniters

  Garage & Shop Heaters

  Infrared Heaters
  Outdoor Heater

  Portable Heaters
  Replacement Parts

  Specialty Heaters

  Thermostats

  Unit Heaters
  Wall Heaters

  More
...

Lighting

  Machine & Tool Lights
  Loading & Docking Lights

  Portable Utility Lights

  More...

Restroom Supplies
  Baby Changing Tables
  Electric Hand Driers
  Faucets
  Soap Dispensers
  Towel Dispensers
  More...

Ventilation

  Air Curtains

  Attic Fans

  Blowers

  Ceiling Fans

  Circulators

  Duct Fans

  Evaporative Coolers

  Exhaust Fans

  Floor & Oscillating Fans

  Personal Fans

  Misting Systems

  Roof Ventilators & Curbs

  Wall Exhaust Fans

  Workstation Fans

  More...
 


 

Single Element Quartz


Outdoor / Indoor Rated Quartz Tube Infrared Heaters


Commercial
 

• UL/C-UL listed for suspended, totally exposed (outdoor) and indoor spot heating applications.
 

• Frosted Quartz Tube heating element (included).
 

• 60° Symmetric heat pattern.
 

• Finish: High-temp brown powder coated finish or corrosion resistant stainless steel 24-gauge housing.
 

• Gold anodized aluminum reflector and end caps.
 

• Painted Brown models are direct wire and include (3) 24” long lead wires for field connections in a remote enclosure (not supplied). Optional electrical box enclosure is available for this series to allow for direct wire connection to the end of the heater housing.

• Stainless steel models include an electrical enclosure assembled to the end of the heater housing and (2) 6” long lead wires for direct field connection.

• Two 2’ ft. long mounting chains and four S-Hooks included.
 

• The OCH-Series can be surfaced mounted using the supplied
mounting brackets which allow up to a 45º horizontal tilt adjustment.
 

• Three different mounting options available: Chain Mount (supplied, as shown) Wall Mount, Ceiling Mount

 

Click on the part number below to order.

Part#

Model#

Watts

BTU's

Volts

Amps

Quartz
Replacement Tubes

Price

480444 OCH-46-120V 1500 5120 120 12.5 671-3784

$132.00

480451 OCH-46-208V 2000 6826 208 9.6 671-5061 $132.00
480468 OCH-46-240V 2000 6826 240 8.3 671-3785 $132.00
480475 OCH-46-277V 2000 6826 277 7.2 671-5018 $132.00
480499 OCH-57-208V 3000 10239 208 14.4 671-5060 $153.00
480482 OCH-57-240V 3000 10239 240 12.5 671-3786 $153.00
480505 OCH-57-277V 3000 10239 277 10.8 671-5059 $153.00
480512 OCH-57-480V 2250 7679 480 4.7 671-5058 $153.00
480529 OCH-46-120V-SS 1500 5120 120 12.5 671-3784 $156.00
480536 OCH-46-208V-SS 2000 6826 208 9.6 671-5061 $156.00
480543 OCH-46-240V-SS 2000 6826 240 8.3 671-3785 $156.00
480550 OCH-46-277V-SS 2000 6826 277 7.2 671-5018 $156.00
480574 OCH-57-208V-SS 3000 10239 208 14.4 671-5060 $173.00
480567 OCH-57-240V-SS 3000 10239 240 12.5 671-3786 $173.00
480581 OCH-57-277V-SS 3000 10239 277 10.8 671-5059 $173.00
480598 OCH-57-480V-SS 2250 7679 480 4.7 671-5058 $173.00


Optional Accessories:

Part#

Model#

Description

For Use With

Price

480888 OCHWG-46 Stainless Steel Wire Guards OCH-46 Series Models $25.00
480895 OCHWG-57 Stainless Steel Wire Guards OCH-57 Series Models $26.00
881128 VMB-41-SS Wall Mtg. Brackets (2) ALL OCH Models $86.00
485357 VHC-32 Variable Heat Controller ALL OCH Models $187.00
871556 OCH-EBK-120 Enclosure w / cord & plug OCH 120V Models $33.00
871563 OCH-EBK-208 Enclosure w / cord OCH 208V Models $33.00
871570 OCH-EBK-240 Enclosure w / cord & plug OCH 240V Models $33.00
871587 OCH-EBK-480 Enclosure Only OCH 277/480V Models $25.00

 

Application Solutions:

Commercial
Stainless Steel Models for additional corrosion resistance in outdoor applications.

Dimensions

Heater Series Length Width Height
OCH-46 42.0" 5.4" 6.5"
OCH-57 53.0" 5.4" 6.5"


• Outdoor spot heating for patio areas, bus shelters, smoking areas, etc.

• Indoor spot heating for over workstations, lobby entrance ways, and vestible areas; including process applications for parts.

• To achieve optimum infrared heating results, do not exceed mount heights of 12’ and tilt heaters 15-20° inward towards target.


Commercial          Commercial



Sizing Chart

  Heat Pattern @ Floor Level  

Mounting Height

Heater Model

Watts

Length

Width

Sq. Ft.

Total Watts / Sq. Ft.

7' OCH-46 1500 11 9 99 15.2
7' OCH-46 2000 11 9 99 20.2
8' OCH-46 1500 12 10 120 12.5
8' OCH-46 2000 12 10 120 16.7
8' OCH-57 3000 13 10 130 23.1
8' OCH-57 2250 13 10 130 17.3
9' OCH-46 1500 13 11 143 10.5
9' OCH-46 2000 13 11 143 14.0
9' OCH-57 3000 14 11 154 19.5
9' OCH-57 2250 14 11 154 14.6
10' OCH-57 3000 15 12 180 16.7
10' OCH-57 2250 15 12 180 12.5
12' OCH-57 3000 17 14 238 12.6
12' OCH-57 2250 17 14 238 9.5


Total Area / Building Heating

Average: 8-20 Watts per Square Foot
Calculation: Sq. Ft. of Area x .5 x Desired Temp Rise* = Total Watts Required.
* - Desired Temperature Rise = Desired Comfort Level - Outside Design Temp
Principles of Total Area / Building Heating:
~Always complete a "Heat Loss Calculation" ~Avoid mounting below 8' ft.
~Concentrate heat on perimeter areas ~Avoid mounting unit directly over an individual's head



Indoor Spot Heating

Average: 25-60 Watts per Square Foot
Calculation: Sq. Ft. of Area x 1 x Desired Temp Rise = Total Watts Required.
Principles of Indoor Spot Heating:
~Always cross beam patterns ~Avoid mounting below 8' ft.
~Always try to heat from both sides of object ~Avoid mounting unit directly over an individual's head



Outdoor Spot Heating

Average: 2 Watts per Square Foot per Desired Temp. Rise
Calculation: Sq. Ft. of Area x 2 x Desired Temp Rise = Total Watts Required.
Principles of Outdoor Spot Heating:
~Use Quartz Lamps or Quartz Tubes ~Never use 90-Degree Patterns
~Always use the MTM, OCH & RPH Heaters ~Strive for Blanket Coverage of Area



Snow and Ice Control Heating System

Average: 85-110 Watts per Square Foot
Calculation: Sq. Ft. of Area x Required Watts / Sq.Ft.* = Total Watts Required.
* - Required Watts = Table B Result (Table A: Factor I + Factor II)
Principles of IR Snow & Ice Control Systems:
~Always use Quartz Lamps ~Never use 90-Degree Patterns
~Always use the Mul-T-Mount Heater ~Never Mount Above 16' ft.
~Strive for Blanket Coverage of Area

 

 

HACKER SAFE certified sites prevent over 99.9% of hacker crime.

Shopping Cart
Your cart is empty.
Mailing Lists
I received my heater this morning - less than 24 hours after placing the order!  That is amazing service.  Thank you for your prompt response.  Your company will be among my "favorites" for Internet orders.

Dan